SPR-PVC-AS

Protective metal conduit, strip-wound.
S profile, PVC sheathing

Material: Cold strip galvanized | PVC
Temperature: -25°C ... +90°C^ +100°C
IP class [acc. to EN 60529]: IP 68

SPR-PVC

Protective metal conduit, strip-wound.
S profile, PVC sheathing

Material: Cold strip galvanized | PVC
Temperature: -25°C ... +90°C^ +100°C
IP class [acc. to EN 60529]: IP 68

SPR-PA

Protective metal conduit, strip-wound.
S profile, PA sheathing

Material: Cold strip galvanized | PA
Temperature: -50°C ... +120°C^ +150°C
IP class [acc. to EN 60529]: IP 68

SPR-PU-AS

Protective metal conduit. strip-wound.
S profile, PU sheathing, V2 (UL 94)

Material: Cold strip galvanized | PU
Temperature: -50°C ... +100°C^ +130°C
IP class [acc. to EN 60529]: IP 68

SPR-PU-F

Protective metal conduit.
S profile, flame retardant PU sheathing, V0 (UL 94), EN 45545-2 (R22;HL2), (R23;HL3)

Material: Galvanized steel | PU
Temperature: -50°C ... +100°C^ +130°C
IP class [acc. to EN 60529]: IP 68

SPR-PVC-EDU-AS

Protective metal conduit. strip-wound.
S profile, PVC sheathing, galvanized steel wire braiding

Material: Cold strip galvanized | PVC | Galvanized steel
Temperature: -25°C ... +90°C^ +100°C
IP class [acc. to EN 60529]: IP 68

FLEXAgraff-PU-AS

Protective metal conduit, strip-wound.
Double overlapped profile (Agraff), PU sheathing, V2 (UL 94)

Material: Cold strip galvanized | PU
Temperature: -50°C ... +100°C^ +130°C
IP class [acc. to EN 60529]: IP 68

FLEXAgraff-PU-F

Protective metal conduit, Strip-wound.
Double overlapped profile (Agraff), PU sheathing, flame retardant, V0 (UL 94), EN 45545-2 (R22;HL2), (R23;HL3)

Material: Cold strip galvanized | PU
Temperature: -50°C ... +100°C^ +130°C
IP class [acc. to EN 60529]: IP 68

FLEXAgraff-SI-ASF

Protective metal conduit, strip-wound.
Double overlapped profile (Agraff), SI sheathing

Material: Cold strip galvanized | SI
Temperature: -50°C ... +180°C
IP class [acc. to EN 60529]: IP 68

FLEXAgraff-CU-PU

Protective metal conduit, strip-wound.
Double overlapped profile (Agraff), copper wire braiding, PU sheathing, for EMC applications

Material: Cold strip galvanized | CU | PU
Temperature: -50°C ... +100°C^+130°C
IP class [acc. to EN 60529]: IP 68

LIQUID-TIGHT-EF

Protective metal conduit, strip-wound.
Hooked profile, special fibre sealing, smooth, reinforced, flame-resistant PVC sheathing

Material: Cold strip galvanized | PVC
Temperature: -25°C ... +90°C^+100°C
IP class [acc. to EN 60529]: IP 68

LIQUID-TIGHT-EF-OR

Protective metal conduit, strip-wound.
Hooked profile,, special fibre sealing, smooth, oil-resistant PVC sheathing

Material: Cold strip galvanized | PVC
Temperature: -25°C ... +90°C^+100°C
IP class [acc. to EN 60529]: IP 68

LIQUID-TIGHT-UL-CSA

Protective metal conduit, strip-wound, hooked profile, incorporated copper ground lead, smooth rein-forced PVC sheathing

Material: Galvanized steel | PVC
Temperature: -25°C ... +90°C^+100°C
IP class [acc. to EN 60529]: IP 68

LIQUID-TIGHT-FOOD

Protective metal conduit, strip-wound.
Hooked profile, special fibre sealing, liquid tight, smooth, food-safe PU sheathing

Material: Cold strip galvanized | PU
Temperature: -40°C ... +80°C^+110°C
IP class [acc. to EN 60529]: IP 68